ISSUE: IMR Batteries "end" charge prematurely - See T# 1768861 for CASE Study



1. Remove all batteries from the charger
2. Use a dry clean cloth to wipe both the positive and negative ends of the batteries
3. Install two batteries into the first two channels of the charger and let it charge 3-4 hours to see if they will be fully charged.
You can ignore the "poor" reading. The charger measures the internal resistance of the battery, which can be impacted by the contacts between the terminals.
4. If these two batteries charge properly, you can test charging all batteries simultaneously.

If the issue persists, move forward with standard warranty/replacement steps.